SLPSystematic ReviewCoDAS2023

Quantitative approach to analyze hyoid bone movement during swallowing by ultrasound: an integrative review.

Desiré Dominique Diniz de Magalhães, Jayne de Freitas Bandeira, Leandro Pernambuco

PMID 37466503

WHAT IT FOUND

Ultrasound is increasingly used to measure hyoid bone movement, but there is no standard way to do it.

Different studies used different equipment, transducer positions, and software, making results impossible to compare. Amplitude is the most common measure, but extraction methods vary widely.

Key findings

01There is no standardized method for using ultrasound to measure hyoid bone movement, with high variability in equipment, transducer positioning, and analysis software.

02Amplitude is the most frequently investigated measure of hyoid bone movement, followed by time and velocity.

03Reliability was only investigated in six of the 26 included studies, and results were not comparable due to differing methods.

STILL TO COME

How it was doneWhat they foundWhat it means for SLPs

Read the rest of this summary

You get three full summaries a month, free, and we do not ask for a card. Search, the TL;DRs and your library stay unlimited either way.

Already have one?

What it does not show

The review did not assess the quality or risk of bias of the included studies. Heterogeneity in equipment and methods prevented any meta-analysis or direct comparison of results. Most included studies were conducted on healthy populations, limiting generalizability to patients with dysphagia. Reliability data was sparse, present in only six of the 26 studies.

Declared interests

The authors declared no conflicts of interest. The study was funded by the Coordination for the Improvement of Higher Education Personnel (CAPES) and the National Council for Scientific and Technological Development (CNPq).

The easy way to misread this

Do not assume that ultrasound measurements from one study or clinic are directly comparable to another. The lack of standardized methods for transducer placement and image analysis means that a 'normal' amplitude score in one setting may not mean the same thing in another.