PTOtherJournal of physical therapy science2017

Influence of the ultrasound transducer tilt on muscle thickness and echo intensity of the rectus femoris muscle of healthy subjects.

Hiroshi Ishida, Tadanobu Suehiro, Keita Suzuki and 2 others

PMID 29643602

WHAT IT FOUND

Ultrasound probe tilt by 6 or 9 degrees did not detect a change in muscle thickness, but did change echo intensity in 14 healthy young men.

Keep probe angle consistent when comparing echo intensity.

Key findings

01Transducer tilt changed echo intensity, but not muscle thickness.

02Muscle thickness differences were not larger than the minimal detectable change.

03Echo intensity differences were larger than the minimal detectable change except between the reference and +3° conditions.

STILL TO COME

How it was doneWhat they foundWhat it means for PTs

Read the rest of this summary

You get three full summaries a month, free, and we do not ask for a card. Search, the TL;DRs and your library stay unlimited either way.

Already have one?

What it does not show

Only 14 healthy male volunteers were tested, and they were young physiotherapy students. The study did not test older individuals with sarcopenia, the group mentioned in the introduction. The study did not include women, so the influence of gender remains unknown. Only the rectus femoris was tested, and muscle fiber direction differs among muscles. Transducer rotation and medial/lateral tilt were not measured exactly. The reference angle was chosen subjectively to make the rectus femoris look more hyper-echoic.

The easy way to misread this

Do not read a change in echo intensity between scans as a real change in the muscle. In these healthy young men, cranial transducer tilt changed echo intensity at +6° and +9°, and only healthy young men were tested.

Read it on PubMed →