Factors Influencing Speech Perception in Adults With a Cochlear Implant.
Floris Heutink, Berit M Verbist, Willem-Jan van der Woude and 6 others
PMID 33480623WHAT IT FOUND
Adult cochlear implant users with precurved electrodes had better speech perception scores than users with straight electrodes.
The electrode was chosen clinically, not randomly, so this shows an association, not that the electrode itself caused better hearing.
Key findings
01The precurved group had a higher median CVC50 speech score in quiet than the straight group.
02After accounting for age, education, years of hearing loss, preoperative CVC score, preoperative and postoperative hearing thresholds, and scalar trajectory, the precurved electrode was associated with a CVC50 score 11.8 percentage points higher than the straight electrode.
03The groups were not randomly assigned: patients with residual hearing were generally given the straight electrode, and patients without residual hearing were given the precurved electrode.
STILL TO COME
How it was doneWhat they foundWhat it means for SLPs
Read the rest of this summary
You get three full summaries a month, free, and we do not ask for a card. Search, the TL;DRs and your library stay unlimited either way.
What it does not show
The study was observational and not randomised, so the electrode groups differed before implantation. Patients with residual hearing were generally given the straight electrode, and patients without residual hearing were given the precurved electrode, creating selection bias. The analysis was limited to two electrode types from one manufacturer, so it may not apply to other CI systems. Some factors that can affect speech perception, such as cognition and brain plasticity, were not measured. The groups were small after stratification, especially the straight electrode group with 44 participants, so some correlations may have been missed. The time since implantation varied from 14 to 92 months. Nine participants were excluded from the main multivariable model because of missing data or poor-quality scans. The duration of severe to profound hearing loss was not evaluated because patients could not reliably recall its onset.
Declared interests
The authors declared no conflicts of interest. The Radboudumc department received an ongoing institutional grant from Cochlear Ltd, and the institutional grant from Cochlear Ltd was used for this study. The department also reported past or ongoing grants from Advanced Bionics Corp, Oticon Corp, and Med-el Corp.
The easy way to misread this
Do not read the 11.8 percentage point difference in the model as proof that the precurved electrode caused better speech perception. The electrode was chosen clinically, not randomly, and the precurved group had poorer preoperative hearing thresholds, so selection and implant position cannot be separated.