PTOTSLPOtherFrontiers in rehabilitation sciences2023

A modified two-dimensional sensory organization test that assesses both anteroposterior and mediolateral postural control.

Andrew R Wagner, Daniel M Merfeld

PMID 37284337

WHAT IT FOUND

A new balance test that moves the platform sideways as well as forward and back causes much greater side-to-side sway than the standard version.

This confirms it successfully challenges the body's ability to sense sideways position, filling a gap in assessing fall risk.

Key findings

01The modified test increased side-to-side sway significantly more than the standard test in both wide and narrow stances.

02Forward-backward sway did not differ significantly between the modified and standard tests, showing the change was specific to the sideways direction.

03When compared to standing still, the modified test caused sway to increase by a factor of 2.99 to 6.26, whereas the standard test only increased it by 1.25 to 1.84.

STILL TO COME

How it was doneWhat they foundWhat it means for PTsWhat it means for OTsWhat it means for SLPs

Read the rest of this summary

You get three full summaries a month, free, and we do not ask for a card. Search, the TL;DRs and your library stay unlimited either way.

Already have one?

What it does not show

The study was conducted on young, healthy adults, so the results may not apply to older adults or people with balance disorders. The test used a virtual reality headset and a motion platform, which differs from standard clinical equipment. The study did not test whether this new method actually predicts falls or diagnoses conditions better than existing tests. The number of participants was small (21).

Declared interests

Funding was provided by NIH/NIA and DoD CDMRP grants. One author received a scholarship from the Foundation for Physical Therapy Research. No commercial conflicts were declared.

The easy way to misread this

Do not assume this new test is ready for clinical use or that it diagnoses balance disorders. The study only showed that the test mechanically works as intended in healthy young people; it did not test patients or prove that the extra sway predicts falls.

Read it on PubMed →