PTSystematic ReviewPhysiotherapy research international : the journal for researchers and clinicians in physical therapy2025

The Reliability of Using a Handheld Device to Measure 2D Kinematics: A Systematic Review.

Lee T Atkins, Mark Wilhelm, Casey Base and 6 others

PMID 40568733

WHAT IT FOUND

Phone and tablet video measured some lower-limb angles reliably, but agreement ranged from poor to excellent depending on the joint and movement.

Frontal plane knee angle in single-leg tasks held up best; hip angle in running was worst.

Key findings

01Agreement between raters and within the same rater swung from poor to excellent, depending on which angle, which activity and which moment in the movement was measured.

02The frontal plane knee angle during single-leg tasks was the most reliable measure, with excellent agreement between raters for a single-limb stepdown and for single-leg drop jumping, hopping and cutting.

03The hip was the weak point in running: raters agreed poorly on frontal plane hip angle while sagittal knee angle was moderate.

STILL TO COME

How it was doneWhat they foundWhat it means for PTs

Read the rest of this summary

You get three full summaries a month, free, and we do not ask for a card. Search, the TL;DRs and your library stay unlimited either way.

Already have one?

What it does not show

Only eight studies were found, and their agreement statistics were described in words rather than pooled, so there is no single estimate of how reliable these measures are. Almost everyone measured was free of symptoms: of 189 participants, only 12 had had an anterior cruciate ligament reconstruction and 40 had anterior knee pain. There is little here about people with other conditions or more severe disability. Most studies did not say whether raters were blinded to each other's measurements or to their own earlier ones, and four did not describe the raters' experience, so some of the agreement reported may be inflated. Only two of the eight studies reported the camera's resolution and set-ups varied widely, so the review could not work out which device or app feature actually drives reliability. The review measured whether raters agree with each other, not whether the angles they record are correct. Camera alignment error was not tested in these studies. Whether holding the device by hand rather than mounting it matters was never tested directly; it can only be inferred from comparing studies that did it differently.

Declared interests

The authors declare no conflicts of interest. For the ethics statement and consent they state only that they have nothing to report. No funding source is reported anywhere in the text supplied.

The easy way to misread this

Do not read this as showing that phone video gives accurate joint angles. The review only checked whether different raters agreed with each other, and it warns that tilting a camera by 2 degrees can shift a measured limb angle by as much as 1 degree. Agreement between raters is not the same thing as measuring the right angle.

Summarised by AI from the full paper, without a clinician reviewing it. Check it against the source before it changes what you do. Read it on PubMed →