PTCase SeriesJournal of neuroengineering and rehabilitation2024

Factors leading to falls in transfemoral prosthesis users: a case series of prosthesis-side stumble recovery responses.

Shane T King, Maura E Eveld, Karl E Zelik and 1 others

PMID 39003469

WHAT IT FOUND

Six transfemoral prosthesis users had harness-defined falls in 13 of 24 prosthesis-side stumble trials, including 7 of 11 early swing trials.

Knee buckling and poor base adjustment were common. This is one small case series, not proof.

Key findings

01Six transfemoral prosthesis users had 13 falls in 24 trials, and five of six fell at least once.

02Early swing had the highest fall rate, with 7 of 11 trials resulting in a fall.

03In early swing, most knee angles at ground contact were above 30 degrees, indicating buckling risk.

STILL TO COME

How it was doneWhat they foundWhat it means for PTs

Read the rest of this summary

You get three full summaries a month, free, and we do not ask for a card. Search, the TL;DRs and your library stay unlimited either way.

Already have one?

What it does not show

The study included only six transfemoral prosthesis users, so it cannot describe how most prosthesis users respond. All participants had K3 or greater function, so the results may not apply to lower-function users. A fall was defined as more than 50% body-weight support in the harness, not a true fall to the ground. The overhead harness, treadmill, goggles, noise, and counting task may have changed how participants moved. The treadmill speed was fixed at 0.8 m/s and may not have matched each person's preferred speed. The control group was measured at 1.1 m/s, not the same speed as the prosthesis users. The study was not designed to compare C-Leg users with users of the other two knees, and the paper says device response may not be isolated from the participant response. The proposed stance support, swing extension, flexion initiation, impedance changes, strength, and perturbation training were not tested.

Declared interests

The paper names National Institutes of Health as the funder. The supplied text does not report other conflicts of interest.

The easy way to misread this

Do not read the 54% fall rate as a real-world fall probability. The trials were on a treadmill, the participants were distracted, and a fall was recorded when the harness took more than 50% body-weight support. Do not read the proposed device changes or training ideas as tested interventions.