RNCohortJournal of human lactation : official journal of International Lactation Consultant Association2023

Breastfeeding Perceptions and Behavior Among Postpartum Women Initiating Different Hormonally Systemic Contraceptive Methods.

Susan Frances Wilson, Matthew Ponzini, Machelle Wilson and 3 others

PMID 35786071

WHAT IT FOUND

At the six-month follow-up, breastfeeding rates did not differ significantly between women choosing a hormonal intrauterine device or implant, a DMPA injection, or a non-hormonal method.

DMPA users had lower breastfeeding rates than non-hormonal users at earlier follow-ups.

Key findings

01At the six-month follow-up, any breastfeeding in the hormonal LARC and DMPA groups was not significantly different from the non-hormonal group.

02DMPA users had lower any breastfeeding rates at 6 weeks and 3 months compared with non-hormonal users, even after controlling for baseline breastfeeding intention.

03Decreased milk supply was the most common reason participants gave for stopping breastfeeding, and by 6 months there was no significant difference between groups.

STILL TO COME

How it was doneWhat they foundWhat it means for RNs

Read the rest of this summary

You get three full summaries a month, free, and we do not ask for a card. Search, the TL;DRs and your library stay unlimited either way.

Already have one?

What it does not show

The study included only Medicaid-insured women from one hospital, so results may not apply to privately insured women or other settings. Breastfeeding was self-reported, not objectively measured. Participants were grouped by initial contraceptive choice, but some may have switched methods during follow-up. Women who wanted progestin-only pills were excluded because receipt could not be verified. Many participants could not be contacted for later surveys. Sample size and power were lower at 3 and 6 months. The sample was defined by sex and ability to conceive and did not address gender.

Declared interests

No conflict-of-interest disclosures are reported. The article is categorized as NIH extramural research support.

The easy way to misread this

Do not conclude that DMPA causes breastfeeding failure. The primary six-month breastfeeding outcome was not significantly different between the hormonal groups and the non-hormonal group, and fewer DMPA users reported stopping because of low milk supply than other groups.

Read it on PubMed →

Breastfeeding Perceptions and Behavior Among Postpartum Women Initiating Different Hormonally Systemic Contraceptive Methods. — Applied Evidence